IONTECH EDI Module

Product Introduction

The Iontech®  industrial modules generate mixed bed deionized water through electrodeionization and are specifically designed for industrial applications.

Ionpure modules consistently deliver maximum reliability and superior performance for power, general electronics and laboratory applications without regeneration downtime.

Product Features

● Double O-ring seal guarantees leak-free operation

● Generate mixed-bed quality deionized water without the use of chemicals

● Continuous production instead of batch, with consistent quality

● No need for acid/caustic, neutralization system or exchangable DI tanks

● Superior electrical isolation

100 psi (7 bar), 113˚F (45˚C) continuous operation

Key benefits

● Unlimited chemical in line

● Extra low resistance, Low energy consumption

● Easy replace for IONPURE modules

EDI INLET CONDITIONS

◎ Water : From RO Product

◎ Conductivity (equivalent, including CO2) : <40㎲/㎝

◎ Silica(SiO2)  : <1.0ppm

◎ Iron(as Fe,Mn,S) : <0.01ppm

◎ Max. Total Chlorine(as Cl2) : <0.02ppm

◎ Total Hardness(as CaCO3) : <1.0ppm

◎ Dissolved Organic(TOC as C) : <0.5ppm

◎ pH : 4~11

◎ Temperature : 5~45℃,Recommended 25℃

◎ Inlet Pressure : <100psi(7bar)

 

IT-DS-05

IT-DS-10

IT-DS-20

IT-DS-30

IT-DS-50

Model

Norminal Flow

(M3/HR)

Recovery

(%)

Resistivity

(㏁.㎝)

DC Volt.

(V)

DC AMP.

(A)

0.44

1.1

2.0

3.4

5.1

90~95

≥15

0~55

0~135

0~240

0~320

0~400

0~6

 

MICRONIX EDI Module

EDI INLET CONDITIONS

◎ Water : From RO Product

◎ Conductivity : ≤20㎲/㎝

◎ Recommended Conductivity Range : 2~10㎲/㎝

◎ Maximum Conductivity : ≤30㎲/㎝

◎ pH : 7.0~9.0

◎ Temperature : 5~35℃,Recommended 25℃

◎ Inlet Pressure : 0.15~0.4MPa

◎ Dulite inlet pressure is 0.05~0.1MPa higher than Concentrate outlet pressure

◎ Outlet Pressure : Dulite pressure is 0.05~0.1MPa higher than Concentrate pressure

◎ Hardness : Less than 0.5ppm(when recovery is at 90%, count CaCO3)

◎ Organic Compounds : TOC is less than 0.5ppm, undetectable recommened

◎ Oxidant : Cl2 is less than 0.02ppm; O3 less than 0.01ppm, undetectable recommended

◎ Metal : Less than Fe,Mn,Variable metal ion <0.01ppm

◎ Silica : Less than 0.5ppm

◎ Total CO2 : When less than 3ppm or than 5ppm, water quality is heavily depends on CO2 level & pH

◎ Particle : ≤1㎛

MX-25

MX-50

MX-100

MX-200

MX-300

MX-500

Model

FLOW

(M3/HR)

0.15~0.3

0.3~0.75

0.8~1.4

1.5~2.4

2.5~4.4

4~6

70~85

85~90

90~95

90~95

90~95

90~95

Recovery

(%)

≥15

≥15

≥15

≥15

≥15

≥15

Resistivity

(㏁.㎝)

8~40

15~60

20~100

50~100

90~170

90~170

Volt

(VDC)

≤330

≤330

≤330

≤330

≤330

≤330

Design Volt

(VDC)

0.5~3

0.5~3

1~4

1~4

1~4

1~4

Electricity

(DCV)

6

6

6

6

6

6

Design Electricity

(DCV)