top of page
67c

품목소개 > FILTER & SOFTNER VALVE > TMF-63/67 Series Control Valve

Automatic Filter Control Valve : TMF 67C

Technical Parameter:

Controller model : Time type / Electron type control

Suited pressure : 0.1 - 0.6MPa

Suited water temperature : 5-45℃

Water Capacity : 6m3/h

Tank Diameter Range for Filters : 6”-14”

Water Inlet/Outlet : 1”Female

Drain : 1”Female

Rinse Pipe : 1.05”OD (26.7mm)

Base (The connector for tank) : 2-1/2” 8NPSM

 

Application:

1)Household purify, softener system.

2)Boiler softening water system.

3)Ro pre-treatment system.

4)Swimming pool filters equipment.

5)Ion exchange equipment.

* Certification(s) : CE, ROHS

Automatic Softner Control Valve : TMF 63C

Technical Parameter :

Controller model : Time type / Down-flow

Suited pressure : 0.1 - 0.6MPa

Suited water temperature : 5-45℃

Water Capacity : 4m3/h

Tank Diameter Range for Softener : 6”-18”

Water Inlet/Outlet : 1”Male

Drain : 1/2”Male

Brine Tank Connection : 3/8”Male

Rinse Pipe : 1.05”OD (26.7mm)

Base (The connector for tank) : 2-1/2” 8NPSM

 

Application:

1)Household purify, softener system.

2)Boiler softening water system.

3)Ro pre-treatment system.

4)Swimming pool filters equipment.

5)Ion exchange equipment.

* Certification(s) : CE, ROHS

74a

품목소개 > FILTER & SOFTNER VALVE > TMF-74/75/77 Series Control Valve

Automatic Filter Control Valve : TMF 75A

Technical Parameter:

Controller model : Time type / Electron type control

Suited pressure : 0.1 - 0.6MPa

Suited water temperature : 5-45℃

Water Capacity : 10 m3/h

Tank Diameter Range for Filters : 10”-24”

Water Inlet/Outlet : 2” Male

Drain : 2” Male

Rinse Pipe : 1-1/2"OD(50mm)

Base (The connector for tank) : 4”- 8UN

 

Application:

1)Industrial purify, Sand/Carbon filtering system.

2)Ro pre-treatment system.

3)Swimming pool filters equipment.

4)Ion exchange equipment.

* Certification(s) : CE, ROHS

Automatic Softner Control Valve : TMF 74A

Technical Parameter :

Controller model : Time type / Down-flow

Suited pressure : 0.1 - 0.6MPa

Suited water temperature : 5-45℃

Water Capacity : 10 m3/h

Tank Diameter Range for Softener : 10”-30”

Water Inlet/Outlet : 2” Male

Drain : 1” Male

Brine Tank Connection : 1/2” Male

Rinse Pipe : 1-1/2" OD(50mm)

Base (The connector for tank) : 4”- 8UN

 

Application:

1)Industria purify, softener system.

2)Boiler softening water system.

3)Ro pre-treatment system.

4)Swimming pool filters equipment.

5)Ion exchange equipment.

* Certification(s) : CE, ROHS

Multi-functional Flow Control Valve  : TMF 77A(SOFTNER) / 77B(FILTER)

Technical Parameter:

Controller model : Time type / Electron type control

Suited pressure : 0.15 - 0.6MPa

Suited water temperature : 5-50℃

Water Capacity : 18 m3/h

Tank Diameter Range for Filters : 24”-30

Tank Diameter Range for Softener : 24”-42”

Water Inlet/Outlet : 2” Male

Drain : 77A-1.5” Male(77B-2"Male)

Brine Tank Connection : 3/4” Male

Rinse Pipe : 1-1/2"OD(50mm)

Base (The connector for tank) : 4”- 8UN

 

Application:

1)Household purify, softener system.

2)Boiler softening water system.

3)Ro pre-treatment system.

4)Swimming pool filters equipment.

5)Ion exchange equipment.

* Certification(s) : CE, ROHS

Features :

1. More reliable way of opening and close

2. Keyboard locked function :

   The key set will lock automatic exceed one minute, you must

   open the lock over again when you operate, prevent wrong              operation.

3. It adopts LED dynamic colorful screen :

    The colorful screen flicker express it is in the state of running,           otherwise express it is in the state of regeneration.

4. Prompt power cut secularly :

    Out of electricity exceed three days, you must reinstall the

    currently time when the timepiece flicker ceaselessly, the already     setting time is not changed.

5. No coming water while single pot type control valve                          regeneration

6. Two kinds of counted modes for running :

     Switch the “ON” and “1” which in the electrical control main              board to reach the purpose of running by day or hour.

     It will take effect when restart.

 7. Having output signal connector :

     Via three port of open, close, common down-lead to connect          the electromagnetism valve or increase-pressure pumps.

56AD

품목소개 > FILTER & SOFTNER VALVE > TMF-56A/56D Series Manual Filter Valve

Manual Filter Valve : TMF 56A(1")

Technical Parameter:

● Water Pressure :  0.15 - 0.6MPa

● Water temperature : 5-45℃

● Water Capacity : 4m3/h

● Suitable Tank Diameter : 6”~12”

● Water Inlet/Outlet : 1”Female

● Drain : 1” Female

● Rinse Pipe : 1.05”OD (26.7mm)

● Base (The connector for tank) : 2.5”-8NPSM

 

Application:

1) Residential filteration system

2) Swimming pool filters equipment

3) Sand or Active carbon filter in RO pre-treatment filteration        system

Manual Filter Valve : TMF 56D

Technical Parameter:

● Water Pressure :  0.15 - 0.6MPa

● Water temperature : 5-50℃

● Max. Flow Rate : 10m3/h

● Suitable Tank Diameter : 10”~24”

● Water Inlet/Outlet : 2” Female

● Drain : 1.5” Female

● Rinse Pipe : 1.5"D-GB(50mm) OD

● Base (The connector for tank) : 4”-8UN

Application:

1) Residential filteration system

2) Swimming pool filters equipment

3) Sand or Active carbon filter in RO pre-treatment filteration        system

품목소개 > FILTER & SOFTNER VALVE > TMF-64A/64D Series Manual Softner Valve

64A

Manual Softner Valve : TMF 64A(1")

F64A1.png

Technical Parameter:

● Water Pressure :  0.15 - 0.6MPa

● Water temperature : 5-45℃

● Water Capacity : 4m3/h

● Suitable Tank Diameter : 6”~18”

● Water Inlet/Outlet : 1” Female

● Drain : 1/2” Male

● Brine : 3/8” Male

● Rinse Pipe : 1.05”OD (26.7mm)

● Base (The connector for tank) : 2.5”-8NPSM

 

Application:

1) Residential softening system

2) Ion exchange system 

3) Boiler softening water system

4) RO pretreatment softening system

Manual Softner Valve : TMF 64D(2")

64D.png

Technical Parameter:

● Water Pressure :  0.15 - 0.6MPa

● Water temperature : 5-50℃

● Max. Flow Rate : 10m3/h

● Suitable Tank Diameter : 10”~30”

● Water Inlet/Outlet : 2” Male

● Drain : 1” Male

● Brine : 1/2” Male

● Rinse Pipe : 1.5"D-GB(50mm) OD

● Base (The connector for tank) : 4”-8UN

Application:

1) Residential softening system

2) Ion exchange system 

3) Boiler softening water system

4) RO pretreatment softening system

bottom of page